FIRE HAZARD
The fire suppression
system must be installed,
activated, certified, and
maintained by an
authorized Ansul
®
technician. Do not
attempt to modify or bypass the fire
suppression system. An uncontrolled
fire can cause serious injury or death.
IMPORTANT
1.
The fire extinguisher system must
be set up and charged by an
authorized Ansul
®
technician.
2. The fryer is equipped with a
manual pull station at the lower
rear of the left side of the fryer.
The manual pull station must be in
a line of egress from the fryer. If
the fryer is installed in a location
where the factory installed manual
pull station is not accessible, an
additional remote pull station may
be required by local codes. Any
remote manual pull station must be
installed by an authorized Ansul
distributor in accordance with the
authority having jurisdiction.
BURN HAZARD • SPILLED OIL
The additional remote
pull station must
not be
installed on the front
and/or sides of the fryer,
forward of the ventilator side panels.
Discharge of the fire suppression
system into hot oil will cause hot foam to spill over the
frypot. Serious burns may result from this spillage. Injury
from slipping or falling could also result.
3. The fire suppression system is comprised of a
pressurized container of Ansulex
®
R-102 liquid fire
suppression media along with associated plumbing
and controls. The system utilizes two fusible links for
automatic actuation and a manual pull station for
manual actuation. Two nozzles are used to disperse
the dry chemical fire suppression media.
NOTE: If the fire suppression system is discharged, a
buzzer will sound continuously. The fryer will
remain inoperable until the fire suppression
system is serviced, recharged, and reset by an
authorized Ansul
®
distributor.
Charging the fire suppression system must be in
accordance with Ansul
®
Design, Installation, Recharge
and Maintenance Manual #418086.
4. When the fire suppression system discharges, the fryer
heating element(s) and controls are de-energized and
the fire suppression media is discharged. The fire
suppression media will form an emulsion designed to
both smother and cool the oil.
The primary 450°F (232°C) fusible link is located on the
frypot. This link will melt and discharge the fire
suppression system in the event both the temperature
control thermostat and the high limit control fail. The
secondary 280°F (138°C) fusible link is located in the filter
plenum and will protect against a fire in the plenum.
Melting of either link will discharge the fire suppression
media through both nozzles and cause a buzzer to sound.
NOTE: As an additional fire safety detection device, the
Alto-Shaam fryer includes a sensor located within
the frypot to continuously measure the
temperature of the oil. In the unlikely event of a
simultaneous failure of both the thermostat and
the high limit switch, the sensor will automatically
activate the fire suppression system at
approximately 100°F (38°C) below the oil
temperature ignition point.
Operation and Care Manual #8452/53/55
PG.4
FIRE SUPPRESSION SYSTEM INSTALLATION
FIRE SUPPRESSION SYSTEM. ACCESS
LINK ON ALL MODELS.
ON ALL MODELS.